INITIAL CONDITION

4A-2) DISPLAYING THE CONVERSATION, DOOR-OPENING AND PORTER MODULE

RESET TIME PARAMETERS

This operation allows the values of the conversation, door-opening relay closure and reset
wait time values set in the porter module to be displayed.

Module art. 3072/A
supplied wih terminal
PR connected
to terminal -.

Porter module art. 3062 /
3262/ 3268 supplied
with terminal PR
connected to terminal -.

The module is in the
programming stage:
▲ or ▼ to scroll the menus

to select the menu

to pass to the lower

level menu.

The module is in the
programming stage.

MAIN

SETTINGS

AUDIO TIMING

VALUE: 100

After 3 seconds, the values
of the other parameters are
displayed in sequence.

ON DISPLAY

DESCRIPTION

OPERATION

Select the
MAIN SETTINGS /
SYSTEM PARAM. /
SPEAKER PARAM. /
VIEWING menu.

After the modification
has been made,
remove the
connections between
PR and – on the
3072/A 3062 3262
and 3268 terminals.

If the entry has been made
correctly.

ON DISPLAY

DESCRIPTION

OPERATION

Select the
MAIN SETTINGS/
SYSTEM PARAM. /
DOWNLOAD TYPE menu.

Enter the desired value
using the

▲ or ▼ keys.

EXAMPLE: 1

Press the

key to confirm

the parameter value.

After the modification
has been made,
remove the connections
between PR and – on the
3072/A terminal.

INITIAL CONDITION

4A-3) TYPE OF SERIAL DOWNLOAD
The parameter sets the type of connection used to download the user list.
An RS232 or RS485 interface is available.

Module art. 3072/A
supplied with terminal
PR connected
to terminal -.

The module is in the
programming stage:
▲ or ▼ to scroll the menus

to select the menu

to pass to the lower

level menu.

MAIN

SETTINGS

DOWNLOAD TYPE

VALUE: 0

DOWNLOAD TYPE

VALUE: 1

PARAMETER

CHANGED