3.2.2

Internal DIP-switch and Jumper settings

Disconnect the unit from the power supply.

Remove the four screws on the casing's lower panel and open
the lower lid.

Set the selected keyboard address using the SW1 to SW4
switches of the DIP-switch.

Move the Jumper to the selected position.

Close the casing of the art. 4478A/TAS System Keyboard.






1 2 3 4 5 6 7 8

ON

SW 4

terminated
(120 ohm)

unterminated

SW 3
SW 2
SW 1









KEYBOARD

ADDRESS

SW

1

SW

2

SW

3

SW

4

1

OFF OFF OFF OFF

2

ON

OFF OFF OFF

3

OFF

ON

OFF OFF

4

ON

ON

OFF OFF

5

OFF OFF

ON

OFF

6

ON

OFF

ON

OFF

7

OFF

ON

ON

OFF

8

ON

ON

ON

OFF

9

OFF OFF OFF

ON

10

ON

OFF OFF

ON

11

OFF

ON

OFF

ON

12

ON

ON

OFF

ON

13

OFF OFF

ON

ON

14

ON

OFF

ON

ON

15

OFF

ON

ON

ON

16

ON

ON

ON

ON


3.3 OPTIONAL ACCESSORIES

DB-02 Distribution Box with D-9M Cable Connector to connect
two or more System Keyboards.