Step 5: Configure Interfaces for POE

1. Enter the interface connected to the AP:

RSL_RACK_1_SW(config)#int eth 1/1/20

RSL_RACK_1_SW(config-if-e1000-1/1/20)#

2. Provide a port name description for what is connected:

RSL_RACK_1_SW(config-if-e1000-1/1/20)#port-name Connected to BR-AP7131

3. Enable the port POE:

RSL_RACK_1_SW(config-if-e1000-1/1/20)#inline power

C

ONFIGURING THE

B

ROCADE

RFS7000

C

ONTROLLER

Step 1: Provide power to the controller

Step 2: Set up the controller console port

To add the Brocade Mobility RFS7000 Controller to the network and prepare it for initial configuration:

1. Using the console cable provided, connect the Mobility RFS7000 Controller serial port to an RS-232 (DB-9)

serial port on a separate computer (the “configuration computer”).

2. On the configuration computer, configure a terminal emulation application (such as HyperTerminal):

-

19200bps transfer rate

-

8 data bits

-

No parity

-

1 stop bit

-

No flow control

-

No hardware compression

Step 3: Set the IP address for the controller

1. Connect to the RFS7000 console port.
2. Initial login:

-

login: cli

-

User Access Verification

-

Username: admin

-

Password: admin123

-

Brocade WLAN Controller

-

BR-RFS7000>

3. Enter Privileged Mode

BR-RFS7000>enable

BR-RFS7000#