ALCOVE INSTALLATION


CAUTION:

READ ENTIRE MANUAL BEFORE INSTALLING HEATER.

1. For clearances, see Figure 3. The minimum clearances must be met.

2. For “Installation and Gas Connection”, see page 17.

FOR YOUR SAFETY:

WHAT TO DO IF YOU SMELL GAS


-Do not try to light appliance.

-Do not touch any electrical switch.

-Do not use telephone in building.

-Call your gas supplier immediately, from a neighbor’s phone. Follow the gas supplier

instructions.

-If you cannot reach your gas supplier, call the Fire Department.

-Do not store or use gasoline or any other flammable vapors or liquids in the vicinity of

this appliance or any other appliance.

WARNING:

DO NOT USE THIS ROOM HEATER IF ANY PART HAS BEEN UNDER

WATER. IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT
THE ROOM HEATER AND TO REPLACE ANY PART OF THE CONTROL SYSTEM
AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER.

WARNING:

IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION,

SERVICE, OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE. INSTALLATION AND SERVICE MUST BE PERFORMED
BY A QULIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.

“WARNING:

ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE

DANGEROUS.

NOTE: The depth of the alcove must allow a 4" minimum clearance at the rear. The width of
the alcove must allow a 5” clearance on the right side and the left side. The height of the alcove
must allow for a 10” clearance form the top of the heater to the ceiling of the alcove. The front
edge of the heater must meet the front of the alcove, and have a minimum of 24” to any
combustible material.

NOTE:
DIMENSIONS SHOWN ARE

MINIMUM CLEARANCE TO
COMBUSTIBLE WALL.

FLOOR
PROTECTOR

4"

5"

WALL

STOVE

10"

Figure 3

Page 9