Miter scale indicator adjustment, Kerf insert replacement – Bosch 4212L User Manual

Page 17

Advertising
background image

Miter Scale

Indicator Adjustment

1. Set table at the 0° miter position and tighten miter

lock knob.

2. Raise the head assembly to the full-up position.

3. Loosen the Phillips screw that holds the indicator

in place.

4. Position the indicator to align with the 0° miter

mark and tighten the screw.

Figure: Miter Scale Adjustment

Kerf Insert Replacement

The kerf insert should be close to the blade, in order
to avoid tear-out on the bottom of the workpiece.

To Replace Kerf Insert:

1. Raise the head assembly.

2. Loosen the six (6) kerf screws using the multi pur-

pose tool.

3. Replace kerf insert.

4. Tighten the kerf screws.

NOTE: A new kerf insert does not have a blade slot.
The slot will be created by the tool’s blade. After tight-
ening the kerf screws, switch the saw on and fully
lower the blade into the kerf insert, thereby creating a
blade slot. A “zero-clearance” kerf insert support to
the workpiece, will greatly reduce splintering.

Figure: Kerf Insert

17.

Screw

Access

Hole

Miter

Scale

Indicator

Kerf

Insert

Screws

Phillips

Screwdriver

Advertising