Feedback options, System architecture – ElmoMC SimplIQ Digital Servo Drives-Bell Installation Guide User Manual
Page 12

Bell Installation Guide
Introduction
MAN-BELIG (Ver. 1.302)
12
2.2.3.
Feedback Options
•
Incremental Encoder - up to 40 Mega-Counts per second
•
Digital Halls - up to 2 kHz
•
Incremental Encoder with Digital Halls for commutation - up to 40 Mega-Counts
•
Interpolated Analog Sine/Cosine Encoder - up to 400 kHz
Internal Interpolation - up to x4096
Automatic correction of amplitude mismatch, signal offset
•
Analog Halls
•
Auxiliary Encoder inputs (ECAM, follower, etc.) single-ended, unbuffered
•
The Bell 5 V power supply provides supply voltage (5 V, 200 mA max) for one
Encoder/Resolver/Hall Sensor
2.3. System Architecture
Controller
Main
12-95 VDC
Power supply
Optional
12-95 VDC
Auxiliary supply
I/Os
Communication
RS 232 and CANopen
Power Stage
Current
Feedback
Motor
Auxiliary
Encoder
Incremental
Encoder
Analog
Encoder
PWM
Protection
or
Figure 1: Bell System Block Diagram