Eagle HV Installation Guide
Installation
MAN-EAG-HVIG (Ver. 1.502)
31
3.5.3.3.a
Three-Phase Direct-to-Mains Connection Topology
Figure 6: Non-Isolated Three-Phase Connection Topology
Caution:
•
Do not connect VN- to PE. In a direct-to-mains connection the VN- must
not be connected to the PE. Connecting the VN- to the PE will cause
irreparable damage to the system.
•
Be careful and note that in a direct-to-mains connection the Neutral point
is not the most negative voltage level. It is the mid-point level of the
rectified DC bus.
3.5.3.3.b
Single-Phase Direct-to-Mains Connection Topology
Figure 7: Non-Isolated Single-Phase Connection Topology