Connecting the main power cable – ElmoMC Power Supplies-TAM-100 User Manual

Page 24

Advertising
background image

Tambourine 100 Power Supply

MAN-TAM-100IG (Ver. 1.101)

||

www.elmomc.com

24

Table of Contents

1.14.7. Connecting the Main Power Cable

Figure 10: Main Power Cable Connection

To connect the AC power cable(Figure 10)
1.

For best noise immunity, a shielded (not twisted) cable is recommended (not mandatory)
for the AC input cable.

2.

A 4-wire shielded cable should be used:

a. Connect the 3-phase leads of the main input cable to the L1, L2 and L3 terminals of the

main input connector.

b. For safety requirements, the green/yellow-wire must be connected to the protective earth

(PE terminal). Connect the Protective Earth wire to the PE terminal on the main input
connector.

3.

The gauge of the cable strands is determined by the sum of the actual current
consumption of the drives being fed by the Tambourine 100.