Enerpac ZUTP-Series User Manual

Page 2

Advertising
background image

2

WARNING: Keep hands clear of moving parts and
pressurized hoses.

WARNING: These pumps have internal factory
adjusted relief valves, which must not be repaired or
adjusted except by an Authorized Enerpac Service

Center.

WARNING: To prevent damage to pump electric motor,
check specifi cations. Use of incorrect power source
will damage the motor.

2.2 Safety Precautions - Model ZUTP-1500 Pump

DANGER: Failure to observe the following precautions
may result in serious personal injury or death!

• Always wear eye protection, gloves and boots when operating

the pump.

• High pressure hydraulic equipment can be very dangerous if

misused. Keep away from oil leakages at high pressure. Liquid
escaping from highly pressurized equipment has suffi cient
power to penetrate the skin, which can cause blood poisoning.
In the case of such an accident, seek IMMEDIATE medical
attention.

• Never attempt to disconnect a hydraulic

coupler while it is under pressure.

• Never attempt to repair leaks while the

system is pressurized. Be sure system
pressure gauge indicates zero (0) psi/
bar before making any repairs.

• Never pressurize the back of a

disconnected male coupler.
Serious personal injury could
result if the coupler fails while
under pressure.

• Use caution when pressurizing a

system. Pressure can rise faster
than anticipated. Continuously
monitor the pressure gauge during pressurization. Be prepared
to stop pressurization immediately at any time.

• Before operation, ensure that quick-disconnect couplings are

properly connected by physically pulling on them.

• Allow only trained and experienced personnel to operate the

pump. Be especially careful to avoid accidental pump start-up.

• Never leave the pump pressurized and unattended. Always

depressurize before leaving the system unattended.

• Never exceed the safe working pressure for the hydraulic

hoses, tools or pump.

• The Model ZUTP-1500 pump is designed to operate at a

maximum working pressure of 21,750 psi [1500 bar]. Do not
exceed this pressure setting.

WARNING: Do not operate the pump at pressure settings
above 21,750 psi [1500 bar]. Hydraulic components
could rupture or burst. Serious personal injury and

property damage may result!

3.0 SPECIFICATIONS
(See technical data charts at bottom of page)

3.1 Flow, Pressure and Current Draw (typical)

230 V

115 V

0

5,000

[350]

10,000

[700]

15,000

[1000]

21,750

[1500]

20 [0,32]

0

40 [0,65]

60 [0,98]

80 [1,31]

100 [1,63]

120 [1,96]

140 [2,29]

180 [2,94]

160 [2,62]

200 [3,27]

16

14

12

10

8

6

4

2

0

Pressure psi

[bar]

Flow

Curr

ent Draw

(amps)

in /min

3

L /min

Amps (115 V)
Amps (230 V)
Flow

Note: Actual fl ow, pressure and current draw will vary, depending
on power supply, application, pump condition and other factors.

0

0

Technical Data – Model ZUTP-1500

Temperature

Range

Oil Viscosity

Range

Hydraulic

Oil Type

(recommended)

Seal Materials

Max. Hydraulic

Working Pressure

Electric

Current Draw

-20ºF to +140ºF

[-29ºC to +50ºC]

150 -165 S.U.S.

[15 - 25 C.S.T.]

Enerpac HF

Buna, Viton

& Polyurethane

21,750 psi

[1500 bar]

(Refer to graph

in Section 3.1)

Motor

Size

Output Flow Rate

Motor

Electrical

Specifi cations

Sound

Level

Reservoir

Oil Capacity

Weight

With Oil

hp

kW

0 psi

[0 bar]

10,000 psi

[700 bar]

15,000 psi

[1000 bar]

21,750 psi

[1500 bar]

Volts-Ph-Hz

dBA

gallons

liters

lbs

kg

1.7

1.25

180 in

3

/min

[2,94 L/min]

15 in

3

/min

[0,24 L/min]

12 in

3

/min

[0,19 L/min]

8 in

3

/min

[0,13 L/min]

115-1-50/60
230-1-50/60

89

1

3,8

65

29,4

Advertising