Enerpac W35000 User Manual
Page 7
 
7
Fig. F
• Push the release lever (7) back into
the cassette (2). Make sure the ball 
detent clicks into place.
Do not operate the tool if the 
cassette release lever is not fully 
closed.
3.4 To connect the hoses (fig. F)
Make sure all accessories meet 
the pressure requirements.
Make sure the quick connect 
couplings are securely attached 
before operating the tool.
The tool is fitted with male and female 
quick-connect couplings. Use Enerpac 
twin safety hoses only. Refer to the 
table below:
Enerpac hose
model number
Description
THQ-706T
Two hoses, 6 m
(19.5 feet) long
THQ-712T
Two hoses, 12 m
(39 feet) long
• Remove the hose dust caps.
• Connect the hose with the female 
coupling (15) to the advance 
coupling (4).
• Pull the sleeve on the female
coupling of the hose over the 
advance coupling.
• Tighten the sleeve.
• Connect the hose with the male 
coupling (16) into the return 
coupling (5).
• Pull the sleeve on the return coupling
over the male coupling of the hose.
• Tighten the sleeve.
• Fit the hoses to the pump. 
Refer to the pump instruction 
manual.
Fig. E
Fig. D