Bunn VPS User Manual

Page 5

Advertising
background image

Page 5

TROUBLESHOOTING

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems

encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.

•

Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel.

•

This brewer is heated at all times. Keep away from combustibles.

WARNING – • Exercise extreme caution when servicing electrical equipment.

• Unplug the brewer when servicing, except when electrical tests are specified.
• Follow recommended service procedures
• Replace all protective shields or safety notices

PROBLEM

Water is not hot

Spitting or excessive steaming

PROBABLE CAUSE

1. Limit Thermostat or Thermal
Cut-Off
CAUTION - Do not eliminate or
bypass limit thermostat/thermal
cut-off. Use only BOM replace-
ment part.
Limit Thermostat - #29329.7000

2. Control Thermostat

3. Tank Heater

1. Lime Build-up
CAUTION - Tank and tank
components should be delimed
regularly depending on local
water conditions. Excessive
mineral build-up on stainless
steel surfaces can initiate corro-
sive reactions resulting in
serious leaks.

2. Control Thermostat

REMEDY

Refer to

Service

- Limit Thermo-

stat or Thermal Cut-Off for
testing procedures. See page 10
or 13

Refer to

Service

- Control Ther-

mostat for testing procedures.
See page 9

Refer to

Service

- Tank Heater

for testing procedures. See page
12

Inspect the tank assembly for
excessive lime deposits. Delime
as required.

Refer to

Service

- Control Ther-

mostat for testing procedures.
See page 9

10053 022300

Advertising