ETC Sensor3 Battery Backup Unit User Manual

E t c, Sensor, 3 battery backup unit installation guide

Advertising
background image

E T C

®

S e t u p G u i d e

Sensor

®

3 Battery Backup Unit Installation Guide

Sensor3 Battery Backup Unit Installation Guide

Page 1 of 4

Electronic Theatre Controls, Inc.

Corporate Headquarters

3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA

Tel +608 831 4116

Fax +608 836 1736

London, UK

Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK

Tel +44 (0)20 8896 1000

Fax +44 (0)20 8896 2000

Rome, IT

Via Pieve Torina, 48, 00156 Rome, Italy

Tel +39 (06) 32 111 683

Fax +39 (06) 32 656 990

Holzkirchen, DE

Ohmstrasse 3, 83607 Holzkirchen, Germany

Tel +49 (80 24) 47 00-0

Fax +49 (80 24) 47 00-3 00

Hong Kong

Rm 1801, 18/F, Tower I Phase 1 Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong

Tel +852 2799 1220

Fax +852 2799 9325

Service: (Americas)

[email protected]

(UK)

[email protected]

(DE)

[email protected]

(Asia)

[email protected]

Web:

www.etcconnect.com

QSF 4.1.9.1

Copyright © 2010 ETC. All Rights Reserved.

Product information and specifications subject to change.

7140M2180

Rev A

Released 2011-12

Introduction

This guide illustrates installation of the Sensor

®

3 Battery Backup Unit. This unit should be placed

in the vicinity of your Sensor3 dimmer racks.

The Sensor

®

3 Battery Backup Unit provides battery power to CEM3 control modules for up to 45

minutes during power outages, thereby facilitating an instantaneous recovery after power has
been restored. Each Battery Backup Unit may be fitted with one or two batteries; each battery
feeds one Sensor3 rack.

Required tools:

• Slotted screwdriver
• Precision slotted screwdriver
• No. 2 Phillips screwdriver
• Small extension (dental) mirror
• Wire strippers for 14-18 AWG (1.5-2.0mm

2

) wire

• Wire cutters

Required materials (not provided):

• Appropriate mounting hardware for attaching unit to wall
• 14-18 AWG (1.5 - 2.0mm

2

) twisted pair of adequate length for wire run

• 3/4” or smaller conduit of adequate length for wire run
• Conduit sleeves (2)

Procedure

This procedure is broken down into the following subsections:

Preparation on page 1

Mount Unit to Wall on page 2

Install Conduit from Unit to Sensor3 Rack on page 2

Connect the Battery Leads on page 2

Run Wire from Unit to Rack on page 3

Install Battery Pack(s) on page 4

Finishing Touches on page 4

Preparation

Step 1:

Turn off power to the rack. Before removing dimmer or control modules for

service, de-energize main feed to dimmer rack and follow appropriate Lockout/

Tagout procedures as described in NFPA Standard 70E. It is important to note

that electrical equipment such as dimmer racks can present an arc flash safety

hazard if improperly serviced. This is due to available large short circuit

currents on the feeders of the equipment. Any work on energized equipment

must comply with OSHA Electrical Safe Working Practices.

W A R N I N G :

RISK OF ELECTRIC SHOCK! Failure to disconnect all power to the rack

before working in the rack could result in serious injury or death.