Operating instructions safety system ces-az-als, Evaluation unit ces-az-als-04b, Dimension drawing switching characteristics ì – EUCHNER CES-AZ-ALS-xxx (Unicode) User Manual
Page 23: Housing for din rail mounting, ip 20, Relay output, 4 read heads can be connected, Door monitoring outputs n-switching

Operating Instructions Safety System CES-AZ-ALS-...
23
Evaluation unit CES-AZ-ALS-04B
Ì
Housing for DIN rail mounting, IP 20
Ì
Relay output
Ì
4 read heads can be connected
Ì
Door monitoring outputs n-switching
Dimension drawing
Switching characteristics
Ì
2 safety outputs
with 2 NO contacts each
(relay outputs)
Ì
4 door monitoring outputs
(semiconductor outputs,
n-switching,
not safety outputs)
45
99
114
24
Y2
O2
Y1
O1
23
STATE OUT DIA
+UB
0V
SH1
SH2
H12
H22
H11
H21
14
DIA
J2
TST
J1
13
S
CES - AZ
H1
H2
H3
H4
S
Y
Safety Unit
RESET
Unicode
H31
H41
H32
H42
SH3
SH4
O3
O4
Suitable for 35-mm DIN rail according to EN 60715
Safety guard
closed
(all actuators detected)
open
(e.g. actuator 1 not in the oper-
ating distance)
Read head 1
Actuator 1
Read head 1
13
14
23
24
0 V
O 1
13
14
23
24
0 V
O 1
0 V
O 2
0 V
O 2
0 V
O 3
0 V
O 3
0 V
O 4
0 V
O 4