System status table, System manual safety system ces-a-w5h-01 – EUCHNER CES-A-W5H-01 (Multicode) User Manual
Page 18
Advertising

System Manual Safety System CES-A-W5H-01
18
System Status Table
Operating mode
Actuator/ Guar
d position
Safety outputs LA and LB
PLC
LED display
State
Output
OUT (status signal)
ST
ATE (gr
een)
OUT/ERROR (yellow)
OUT/ERROR (r
ed)
Normal operation
closed
on
1
Normal operation, door closed
open
off
0
Normal operation, door open
State indication
X
off
0
3 x +
Self-test after operating voltage is applied
Fault display
X
off
0
Device-internal component failure or
excessively high interference (EMC) or short circuit/external power at
the LA/LB safety output
Key to symbols
N
0 Volt or not connected
1
4 Volt
0
0 Volt
LED is not lit
LED is lit
3 x +
LED flashes three times and then lights up continuously
X
Any state
Advertising