Switching distances
Operating distance for center offset m = 0
(only in combination with actuator CES-A-BBA/CES-A-BCA)
Parameter
Value
Unit
min.
typ.
max.
Switch-on distance
-
20
-
mm
Assured switch-on distance s
ao
1)
18
-
-
Switching hysteresis
1)
2
3
-
Assured switch-off distance s
ar
-
-
40
1) The values apply for surface installation of the actuator.
Typical operating distance
(only in combination with actuator CES-A-BBA/CES-A-BCA)
X
25
15
20
10
5
20
25
30
5
10
15
-30
30
-30
25
20
15
10
5
Y
Z
Figure 4: Typical operating distance
For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm
must be maintained so that the operating distance of the side lobes is not entered.