Functional check – EUCHNER CES-I-AR-U-C04 (Unicode) User Manual
Page 22

Operating Instructions Safety Switch CES-I-AR-U-C04
22
Functional check
After installation and any fault, the safety function must be fully checked. Proceed
as follows:
Warning!
Danger of fatal injury as a result of faults in installation and functional check.
Ì
Before carrying out the functional check, make sure that there are no per-
sons in the danger area.
Ì
Observe the valid accident prevention regulations.
1. Switch on operating voltage.
Ì
The safety switch carries out a self-test.
The green STATE LED flashes for 8 s with 5 Hz.
The STATE LED then flashes at regular intervals.
2. Close all safety guards.
Ì
The machine must not start automatically.
Ì
The green STATE LED illuminates continuously.
3. Enable operation in the control system.
4. Open the safety guard.
Ì
The machine must switch off and it must not be possible to start it as long as
the safety guard is open.
Ì
The green STATE LED flashes at regular intervals.
Repeat steps 2-4 for each safety guard.