EUCHNER CETx-AS-xxx-CB-xxx (Multicode) User Manual
Page 15

Operating Instructions Safety Switch
CET.-AS-...-CB-...
15
Note the following points:
Ì
Actuator and safety switch must be easily accessible for inspection and replace-
ment.
Ì
The switching operation must only be triggered by the specific actuator desig-
nated for this purpose.
Ì
Actuator and safety switch must be fitted so that
Ì
the actuator is positively mounted on the safety guard, e.g. by using the
safety screws included.
Ì
they cannot be removed or tampered with using simple means.
Ì
the active faces of the actuator and the safety switch are parallel to each
other (see figure on the left).
Ì
the actuator is fully inserted into the switch recess when the safety guard is
closed (see figure on the left).
Ì
no dirt can accumulate in the recess.
!