1 replacing a defective as-i safety slave, 2] alt [1] neu* [3 – EUCHNER Safety Basic Monitor User Manual
Page 43

Subject to reasonable modifications due to technical advances
Id.-No.: 114013
Issue date: 14.11.2011
EUCHNER GmbH + Co. KG
43
Kohlhammerstraße 16, D-70771 Leinfelden-Echterdingen
Tel. +49/711/7597-0, Fax +49/711/753316
Safety Basic Monitor
Configuration of the safe inputs
7.3.1
Replacing a defective AS-i Safety Slave
* ’new’ (address ’0’ or ’2’)
Safety In
Adr. 1
Analog Out
Adr. 6
Analog Out
Adr. 5
Safety Output
Module
Slave
Adr. 9/8a
Safety
Basic Device
Power
Supply
AS-i network
Safety In
Adr. 2
Safety In
Adr. 2
Safety In
Adr. 1
Analog Out
Adr. 6
Analog Out
Adr. 5
Safety Output
Module
Slave
Adr. 9/8a
Safety
Basic Device
Power
Supply
AS-i network
Safety In
Adr. 2
Safety In
Adr. 1
Analog Out
Adr. 6
Analog Out
Adr. 5
Safety Output
Module
Slave
Adr. 9/8a
Safety
Basic Device
Power
Supply
AS-i network
SET
>
1s
[2]
alt
[1]
neu*
[3]
SET
>
1s
[4]
[5]