1 write process, Write process, Manual eks electronic-key adapter ethernet – EUCHNER EKS FSA with Ethernet Interface User Manual

Page 35

Advertising
background image

Manual EKS Electronic-Key Adapter Ethernet

8.3.1 Write process

Information!

When this command is used, the Electronic-Key must be in the Electronic-Key adapter and is only
allowed to be removed from within the operating distance after reception of the reply message.

Command message (message core, PC/PLC (control system)

→ EKS, see Figure 8):

f TP (device addr.) (start addr. user data) (number of bytes of user data) (user data)

Reply message (message core, EKS

→ PC/PLC (control system), see Figure 9):

f RF (device addr.) (00

hex

, 00

hex

) (status number)

Content

Byte no.

Description

ASCII

hexadecimal

decimal

0

Number of message bytes

0B ... 7B

11 ... 123

1
2

Command identification

T
P

54
50

84
80

3 Device

address

01

1

4
5

Start address for user data

00

00 ... 70

0

0 ... 112

6

Number of bytes of user data

04 ... 74

4 ... 116

7 ... 122

User data

ASCII or hexadecimal or BCD (code transparent)

Figure 8: Command message write Electronic-Key read/write (message core)

Content

Byte no.

Description

ASCII

hexadecimal

decimal

0

Number of message bytes

07

7

1
2

Command identification

R

F

52
46

82
70

3 Device

address

01

1

4
5

Padding data

00
00

0
0

6 Status

number

*

Figure 9: Reply message write Electronic-Key read/write - status (message core)

* Status number

00

hex

: No

error

02

hex

: Electronic-Key not in the operating distance

(For further status numbers see section 8.5)

100420-02-01/09

Subject to technical modifications

Page 35/40

Advertising