Installation procedure, Product features – FastenMaster TimberLOK User Manual
Page 2

FMTLOKSHEET (0510)
hEAD STyLE
CouNTERSINKS
ITSELF DuRING
INSTALLATIoN
MADE oF hEAT
TREATED STEEL FoR
DRAMATICALLy
INCREASED
STRENGTh AND
DRIvAbILITy
uLTRA-CoATED
FoR uNMATChED
CoRRoSIoN
RESISTANCE.
ACQ APPRovED
AGRESSIvE ThREAD
FoR uLTIMATE
PuLL-DoWN PoWER
Item #
Screw Length
Quantity per Pack
FMTLOK04-12
4"
12
FMTLOK06-12
6"
12
FMTLOK08-12
8"
12
FMTLOK10-12
10"
12
FMTLOK212-50
2
.
1
⁄
2
"
50
FMTLOK04-50
4"
50
FMTLOK06-50
6"
50
FMTLOK08-50
8"
50
FMTLOK10-50
10"
50
FMTLOK212-500
2
.
1
⁄
2
"
500
FMTLOK04-250
4"
250
FMTLOK06-250
6"
250
FMTLOK08-250
8"
250
FMTLOK10-250
10"
250
INSTALLATION PROCEDURE
TimberLok should be installed using a high torque,
1
⁄
2
" variable speed drill (18V if cordless). Choose the proper
length so that threads fully engage the main member or bottom piece. Bring washer head flush to wood
surface or countersink head flush.
Guaranteed Corrosion Resistance
TimberLok is guaranteed not to rust or streak for the life of the project. The fastener has also been tested and
approved for use in ACQ. A guarantee regarding this can be found on www.FastenMaster.com. TimberLok is not
recommended for saltwater applications.
Lateral Design values (Z) for Single Shear Connections
Loaded Perpendicular to Grain
Wood
Specific
Gravity**
FastenMaster
TimberLok
Nails
Lags
10D
16D
20D
1
⁄
4
"
3
⁄
8
"
Red Oak
0.67
299
154
184
222 140
160
Southern Pine
0.55
257
128
154
185 120
140
Doug. Fir-L, SCL*
0.50
240
118
141
170 110
130
Doug. Fir-S
0.46
226
109
131
157 100
120
Hem. Fir
0.43
215
102
122
147 100
120
E. Spruce, W. Cedar
0.36
189
87
104
126 90
100
*SCL = Structural Composite Lumber (LVL, PSL and LSL)
**Wood species indentified typically have average specific gravity similar to the values shown on this table.
All design values based on 1
1
⁄
2
" side member thickness and penetration into main member as follows:
TimberLok 2", Nails 10x diameter, Lags 8x diameter. Design values may be subject to adjustment factors
(section 10.3 in NDS) based on conditions existing during installation as well as those expected during
service life.
The lag screw and nail design values included in these tables are compiled directly from the 2005 National
Design Specification for Wood Construction (2005 NDS).
When using in critical applications, please consult a design professional or refer to our technical bulletins for
the proper spacing and fastening patterns.
The statement “Faster, Easier, Stronger than
3
⁄
8
" lag screws” refers to the comparison of TimberLok design
values in ICC-ES Report #1078 and
3
⁄
8
" lag screws as published in the current NDS.
For technical assistance or questions regarding proper use of this fastener, please contact FastenMaster
Technical Support at 800.518.3569 or visit www.FastenMaster.com.
PRODUCT FEATURES
FASTENMASTER, INC., 153 BOWLES ROAD, AGAWAM, MA 01001
800.518.3569
WWW.FASTENMASTER.COM
FastenMaster
®
and TimberLok
®
are trademarks of OMG, Inc. Copyright © 2010 OMG, Inc. All rights reserved.