I product description, Ii specifi cations – Burnham FREEDOM 101008-01R1-2/07 User Manual
Page 3

3
I Product Description
The FCM070, FCM090 and FCM120 are aluminum gas fi red condensing boilers designed for use in forced
hot water heating systems requiring supply water temperatures of 180°F or less. These boilers are designed for
installation on a wall, however they may be fl oor mounted using an optional pedestal kit available from U.S. Boiler
Company, Inc. This boiler may be vented vertically or horizontally with combustion air supplied from outdoors.
This boiler is not designed for use in gravity hot water systems or systems containing signifi cant amounts of
dissolved oxygen.
II Specifi cations
MODEL*
NO. OF
SECTIONS
MAXIMUM
INPUT
(BTU/hr)
MINIMUM
INPUT
(BTU/hr)
D.O.E.
HEATING
CAPACITY
(BTU/hr)
IBR NET
RATING
(BTU/hr)
AFUE (%)
WATER
VOLUME
(Gal.)
APPROX.
NET
WEIGHT
(lb)
FCM070
mono block
70,000
30,000
63,000
55,000
95.4
0.41
102
FCM090
mono block
90,000
30,000
80,000
70,000
94.5
0.41
102
FCM120
mono block
120,000
40,000
107,000
93,000
95.2
0.62
110
* Add suffi x “N” for natural gas and “P” for propane. Ratings are the same for both fuels.
Using 60/100mm Concentric Vent System Supplied with the Boiler................................................................25 in.
Using Optional 60/100mm Concentric Vent Components:
FCM070 ...................................................................................... 32 ft
FCM090 ...................................................................................... 32 ft
FCM120 ...................................................................................... 18 ft
Using Approved 3” AL29-4C Horizontal Stainless Vent System and Optional Stainless Steel Vent Kit..........55 ft
See Vent Section for additional venting options and requirements
TABLE 2.3: MAXIMUM VENT LENGTHS
TABLE 2.2: SPECIFICATIONS
Figure 2.1: General Confi guration