Disposal

(Please note current regulations)

Parts of the rotary vane pumps and compressors,

shafts, iron or aluminum castings, plastic or glass

parts or bearings, may be recycled as scrap

materials.

Pump Disassembly:

1. Remove the end plate bolts.

2. Remove end plate and check for scoring on end plate,

rotor and body. Surfaces should be smooth. If severe

scoring is visible, contact an authorized service facility.

3. Remove vanes.

4. Clean all surfaces with Gast recommended Flushing

solvent and dry well.

Gast will NOT guarantee field-rebuilt product

performance. For performance guarantee, the product

must be returned to a Gast Authorized Service Facility.
Service Kit contents vary. Most contain vanes, gaskets

oiler wick and filter elements.

SERVICE KIT INSTALLATION

Disconnect electrical power supply cord before
installing Service Kit.

If product is hard wired into system, disconnect
electrical power at the circuit breaker or fuse box
before installing Service Kit.

Disconnect air supply and vent all air lines to
release pressure or vacuum.

Failure to follow these instructions can result in
death, fire or electrical shock.

WARNING

Electrical Shock Hazard

We have Gast Certified Service Centers throughout the world.

For the

most up-to-date listing, contact one of our sales offices :

Gast Manufacturing, Inc.

2300 S. Highway M139

Benton Harbor, MI, 49022

Ph: 269/926-6171

FAX: 269/925-8288

www.gastmfg.com

Gast Hong Kong

Unit 12, 21/F, Block B

New Trade Plaza

6, On Ping Street, Shatin

N. T. Hong Kong

Ph: (852) 2690 1066

Fax: (852) 2690 1012

www.gasthk.com

Pump Reassembly:

1. Apply a light coat of Gast recommended Oil part

#AD220 (an equivalent 10 wt. high detergent oil can

also be used) to the vanes.

2. Re-install vanes, noting the proper direction of the

beveled edge (refer to exploded view).

3. Install end plate and tighten end plate bolts.

4. Install new cover gasket on filter/muffler assembly and

lubricator.

5. Before putting the pump into service, ensure that any

external accessories have not been damaged.

If the pump fails to produce proper vacuum or

pressure, or is excessively noisy, turn off and return