TROUBLESHOOTING CHART

Low

High

Pump

Motor

Reason and remedy

Vacuum Pressure

Vacuum

Pressure

Overheat Overload for problem.

•

•

At pump

•

•

Filter dirty.

Clean or replace.

•

At pump

•

•

Muffler dirty.

Clean or replace.

•

At pump

•

•

Vacuum line collapsed.

Repair or replace.

•

•

•

•

Relief valve set too high.

Inspect and adjust.

•

•

Relief valve set too low.

Inspect and adjust.

•

•

At pump

At pump

•

•

Plugged vacuum/pressure line.

Inspect and repair.

•

•

Vanes sticking.

Clean or replace.

•

•

Vanes worn.

Replace.

•

•

Shaft seal worn.

Replace.

•

•

•

•

Dust or offset powder in pump.

Inspect and clean.

•

•

•

Motor not wired correctly.

Check wiring diagram and line voltage.

•

•

•

•

Running at too high an RPM.

Check wiring diagram and line voltage.