RD7000 Operation Manual 9

3.6.3 Selecting frequencies

It is important to select the correct or appropriate
frequency for your particular application. For more
information see Section 6 or refer to the ABC & XYZ of
locating buried pipes and cables
, which is available as a
free download from www.radiodetection.com

To select a frequency on the receiver:

Switch the unit on by pressing the key,
if you have not already done so.

Press the key to cycle through available
frequencies.

Alternatively, hold down the key and press the
up or down arrows to cycle up or down the range
of frequencies.

If using an active frequency you must also set your
transmitter to output the matching frequency. You can
change your transmitter’s output frequency manually
using your transmitter’s keypad or automatically using
iLOC (iLOC enabled receivers and transmitters only).

To manually select a transmitter output
frequency:

Switch the unit on by pressing the
key, if you have not already done so.

Press the key to cycle through available
frequencies.

NOTE: Some frequencies require that you connect

an accessory, for example an A-Frame, before the

frequency is available.

3.7 TruDepth™ measurement

The RD7000 uses TruDepth to automatically estimate
depth when a good reading is established.

NOTE: TruDepth only indicates a locate depth when

the receiver is correctly oriented directly above the

detected pipe or cable.

Depth readings are displayed according to your preferred
units of measurement as follows:

Less than 1 meter: depth is displayed in centimeters
Greater than 1 meter: depth is displayed in meters.
Less than 3 feet: depth is displayed in inches.
Greater than 3 feet: depth is displayed in feet.

For more information on measuring depth, please refer to
Section 5.

1.

2.

3.

1.

2.




3.8 SideStepauto

SideStepauto allows the transmitter to calculate the
optimum frequency based on ground impedance.
The transmitter uses this information to optimize the
active frequency. SideStepauto helps to improve locate
accuracy by determining the best signal. SideStepauto
can also help to prolong battery life.

NOTE: SideStepauto will only work in direct connection

mode. Inductive frequencies are not supported.

3.8.1 Using SideStepauto

To enable SideStepauto

Switch on the transmitter.

Press the key to enter the menu.

Scroll to the OPT F option using the or

arrows.

Press the key to enter the OPT F menu.

Scroll to the START option using the or

arrows.

Press the key to start SideStepauto and exit
the OPT F menu.

Press the key to exit the menu.

To disable SideStepauto

Switch on the transmitter.

Press the key to enter the menu.

Scroll to the OPT F option using the or

arrows.

Press the key to enter the OPT F menu.

Scroll to the EXIT option using the or

arrows.

Press the key to disable SideStepauto and exit
the OPT F menu.

Press the key to exit the menu.

3.9 Dynamic overload protection

The RD7000PL features dynamic overload protection
(DOP). DOP allows you to locate accurately in areas
with high levels of electromagnetic interference, such
as sub-stations and beneath high-voltage transmission
lines. DOP works by disregarding signal spikes that
would otherwise overwhelm the RD7000PL’s digital signal
processor. DOP is an integrated feature of the RD7000PL.
No action is required by the user.