• The Double Tap Delay is the minimum number of 20mS intervals

required in between taps before a "DOUBLE TAP" event is
reported.

• The Minimum Touch & Hold Duration is the number of 20mS

intervals that a given number of fingers must be "down" in order for
the "TOUCH & HOLD" event to be reported.

• The Momentum Decay is the decay factor applied to motion data

between subsequent 20mS intervals when momentum is active and
no touches are down.

• The Swipe Minimum Move controls the sensitivity of the swipe

detection.

• Moving Average Window Size is the number of data samples used

for smoothing.

• Rotary Slow Start is the number of rotary counts that are ignored

before rotary counts get reported after a direction change or at the
beginning of the rotary gesture. This setting is disabled for the
MTRE.

• Rotary Resolution is the number of rotary counts reported per full

revolution for a single finger sliding around the outside of the touch
screen. This setting is disabled for the MTRE.