Grayhill Modules Dry Contact and Mechanical Relay Output User Manual

Dry contact and mechanical relay output modules, Specifications by package style circuitry

Advertising
background image

Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com

I/O Modules

Dry Contact and Mechanical Relay Output Modules

70L-ODC5R 70G-ODCR/OACRLY 70-ODCR/OACRLY 70M-ODCR

Package Style

Std (70-)

Mini (70M-)

G5 (70G-)

OpenLine

®

(70L-)

Specifications

Units

Isolation Voltage

1

Vrms

1500

1500

1500

1500

Vibration

2

MIL-STD-202

MIL-STD-202

MIL-STD-202

IEC68-2-6

Mechanical Shock

3

MIL-STD-202

MIL-STD-202

MIL-STD-202

IEC68-2-7

Storage Temp. Range

°C

-40 to 70

-40 to 70

-40 to 70

-40 to 70

Operating Temp. Range

°C

-40 to 70

-40 to 70

-40 to 70

-40 to 70

1

Field to logic and channel-to-channel if Grayhill racks are used.

2

MIL-STD-202, Method 204, 20 G, 10-2000 Hz or IEC68-2-6, 0.15 mm/sec

2

, 10-150 Hz.

3

MIL-STD-202, Method 213, Condition F, 1500 G or IEC68-2-27, 11 mS, 15g.

SPECIFICATIONS By PACkAGE STyLE

CIrCUITry

Standard, Mini, G5

OpenLine

®

VAC/VDC

+VCC

INPUT

GROUND

1

2

3

4

5

AMP

LOAD

LOAD

Fuse and status LED in G5 modules only.

AMP

AMP

1

2

3

4

5

6

8

7

9

FEATUrES
• SPST, Normally Open
• UL, CSA Certified
• 1500 Vac Isolation
• G5 and OpenLine

®

Modules Provide

Replaceable 5x20mm Glass Fuse

• Built-in Status LED
• Lifetime Warranty
• Switch AC or DC with the Same Module
• Very Low Off-State Leakage Current for

AC loads

• No Off-State Leakage Current for DC

loads

Advertising