29

E

Setting

Display

Setting

Pre-

range

setting

Primary display (Primary)

ACT/

ACT.

Display value which should remain

S.P.1..

remain permanently in the display:

S.P.4/

"ACT.":

current pressure

MAX

"S.P.1" .. "S.P.4":

switching point 1..4

"MAX":

maximum value

Display filter (Display)

SLOW/

MED.

"SLOW": display reacts slowly to pressure

MED./

fluctuations.

FAST

"MED.": display reacts normally to pressure

fluctuations.

"FAST": display reacts quickly to pressure

fluctuations.

Determining the display range

BAR/

BAR

(RANGE)

PSI/

"BAR":

The pressure is displayed in bar.

FREE

"PSI":

The pressure is displayed in psi.

"FREE": The display range can be defined

by the user. If this setting is

selected, then decimal places

and upper and lower display range

must be set. (see below)

Example: If the display range is

changed to 0..215.5,

the display value 215.5

corresponds to the

nominal pressure of the

unit.

Application: Display of other units

which are proportional

to the pressure

e.g. KN, kg, ...