Example for switch output 1 (normally closed and normally open function):

Abbreviations:

"FH1", "FH2" = upper switch value 1 / upper switch value 2
"FL1", "FL2"

= lower switch value 1 / lower switch value 2

"FNO"

= normally open when window function is active

"FNC"

= normally closed when window function is active


NOTE

:

• It is only possible to set the switch point (SP) if it is higher than the respective

switch-back point (RP). In the case of low SPs we recommend setting the RP
first.

•

The window function only works properly (switching on and off) if all switch
values (including the safety margin) are above 0 bar and below the nominal
pressure range.



6.2

Setting ranges for the switching outputs

Measuring
range

Lower limit of
RP / FL

Upper limit of SP
/ FH

Min. difference
between
RP and SP or
FL and FH

Increment

in psi

in bar

in psi in bar

in psi

in bar

in psi

in bar

in psi in bar

0 .. 500 0.. 25

5

0,25

500

25

5

0,25

1

0,05

0 ..1000 0.. 40

10

0,40

1000

40

10

0,40

2

0,10

0 ..3000 0 ..100

30

1,00

3000

100

30

1,00

5

0,20

0 ..6000 0 ..250

60

2,50

6000

250

60

2,50

10

0,50

0 ..9000 0 ..400

90

4,00

9000

400

90

4,00

20

1,00

0

..600

6,00 600 6,00

1,00

* All ranges given in the table can be adjusted by the increments shown.

Rückschaltwert

Schaltwert

Schaltwert

Rückschaltwert

Sicherheitszone

Sicherheitszone

Ein

Aus

FL1 minus 0,4%FS

FL1

FH1

t

P

Ein

Ein

Aus

Aus

Ein

Aus

FNO

FNC

Schlie

ßerfunktion

Ö

ffnerfunktion

Rückschaltwert

Schaltwert

Schaltwert

Rückschaltwert

Sicherheitszone

Sicherheitszone

Ein

Aus

FL1

FH1

t

P

Ein

Ein

Aus

Aus

Ein

Aus

FNO

FNC

Schlie

ßerfunktion

Ö

ffnerfunktion

FH1 plus 0,4%FS

On

Normally open function

Off

On

Normally closed function

Off

Reverse switch point
Switch point

Switch point
Reverse switch point

Safety zone

Safety zone

Off

On

On

Off

Advertising