HYDAC HDA 5500-0-2-DC-006 (CM1k) User Manual

Page 25

Advertising
background image

HDA 5500 for HLB 1000 and CS 1000

- 25 -

Use the

to change the setting

mode

mode

or

Press mode key

Release mode key

keys

Note:

If when pressing

or

Loc appears in the display, this shows that programming is

disabled. To enable programming, see Point 12 Programming enable.

Hold down

or

to scroll quickly through the values in the display.

12 Programming enables
The unit has two types of programming enable, the operating programming enable and the
main programming enable. Both types must be enabled to change the settings.
The operating programming enable provides protection from unintentional changes to the
settings during normal operation. The operating programming enable can be altered during
operation.
The main programming enable provides general protection from changes to the settings.
The main programming enable can only be altered when switching on the HDA 5500.

12.1 Altering the operating programme enable
Procedure:

During normal operation, press the

and

keys simultaneously and hold down for at

least 3 s.

OPrG (Operating Programming) is displayed.

After approximately 2 s the display changes and the actual setting is displayed:
Free (programming enabled) or Loc (programming disabled).

Within approx. 3 s the setting can be changed to Loc or Free by pressing

or

.

If

or

is not pressed for approximately 3 s or longer, then the displayed setting is

accepted. If a setting has been altered, then ProG (programming) is displayed for
approximately 2 s. This means the changed setting is stored in the HDA 5500. Afterwards
the display returns to normal operation.

3 s

measured value

3 s

Press both arrow

keys simultaneously

and hold down for 3 s

Use

to change setting

Loc

FrEE

= programming disabled

= programming enabled

Display

(release

arrow keys)

2 s

mode

mode

or

Displays

Advertising
This manual is related to the following products: