DIGI-P122 / DIGI-P123 Installation Guide

Access the Web Browser with Defined IP Address

1. Remove the crossover cable between the computer and the DIGI-P122/123.

2. Restore the computer to the previous network settings.

3. Connect the computer and the DIGI-P122/123 to the network.

4. Using Internet Explorer, enter the IP address for the matrix to access the browser

interface.

Additional Options in Web Browser

1. Operation Page:

a. AV switching: You may select an input

channel by pressing the buttons on the

left side of the page.

b. Volume and Mute Control: You may

change the volume and mute status of

the MIC and LINE audio. The level is

indicated in the indicator bars.

c. VGA Auto-Adjust – When a VGA input is

selected, you can press this button, and

the scaler will re-adjust the image.

2. Users tab:

a. Credentials: You can change the

default password for the web browser

interface (GUI). Enter the new

password and press “Save”

b. Front Panel: You can set the front panel

of the DIGI-P122/123 to be locked or

unlocked by pressing the associated

radio button.