Firmware update – Intelix DIGI-P122 User Manual

Page 20

Advertising
background image

DIGI-P122 / DIGI-P123 Installation Guide

Firmware Update

The DIGI-P122/P123 supports firmware updating in the field by USB thumb drive. The

operation is as follows:

1. Connect the DIGI-P122/123 output to a display with a HDMI or VGA cable.

2. Apply power to the DIGI-P122/123.

3. Copy the file “MT23ATV.bin” to a USB flash disk. (The “MT23ATV.bin” file is

provided/authorized by Intelix engineering department)

4. Insert the USB thumb drive into the USB port on the DIGI-P122/123

5. Press the HDMI button on the front panel of the DIGI-P122/123 for 6 seconds OR send

the RS232 command 0698%

6. Press the “OK” button on the IR remote OR send the RS232 command 0609% to confirm

the update procedure.

7. Wait for the update to finish (a progress bar will appear on the screen).

8. Power cycle the DIGI-P122/123 (unplug the power cable, wait three seconds, and plug it

back in)

9. Send the RS232 command 0617% to reset the unit to factory settings.

10. Power cycle the DIGI-P122/123 (unplug the power cable, wait three seconds, and plug it

back in)

Notice: The name of the firmware file must be MT23ATV.bin.