Cabling (continued...)

The following cable specifications apply:

Video: 75Ω Coaxial Cable such as RG59, URM70, RG174 Mini-Coax.
Data: Single Twisted Pair
Power: 2 core. Rated 12VDC - max Current 1A

Individual cables can be run for each of the above, or 'Combination' (Combi)
cables can be used. Iris Innovations supply pre-made cables to length. Please
contact Iris for more details.

Camera Setup:

Before you can control the camera you need to ensure the cameras protocol
details and physical address are correctly set.

By default, the camera leaves the factory set up as follows:

Camera Address: 1

Camera Protocol: Pelco D

Baud Rate: 9600

Iris strongly recommend that the protocol and baud rate are not changed. The
IRIS516 controller will only control the camera with Pelco-D protocol and at
9600 baud.

You may however be required to change the address of the device. Each
camera must have it’s own unique address so that it only responds to
commands destined for it.

Camera Address:

To change the cameras address, remove the panel on the base of the unit and
select the desired address using the DIP switches on bank 2. Bank 2 has 8
switches which are used to select to binary address. A camera address table is
included at the end of this document. Do not alter the settings of the DIP
switches on switch bank 1.