39. HARD-KEY

View the microcontroller’s unique six-character hard-key code.

JS-ICON

Series dimmer racks may be shipped with an invalid hard-key code of

000000. A valid hard-key must be entered before the run time (RTIME) counter

reaches 2160 hours / 90 days. If the run time expires without a valid hard-key the

LCD display will show a runtime counter error (RTC ERR!) and all dimmer control

outputs will be disabled.

HARD-KEY

A dash (-) between hard and key represents a valid hard-key.

HARD KEY

A blank space between hard and key represents an invalid hard-key.

K:XXXXXX

Shows the unique six-character hard-key code (XXXXXX).

K:XXXXXX

Follow the procedure below to enter the menu and modify the hard-key.

K:XXXXXX

Press and hold EXECUTE and then ESCAPE at the same time for 4-5 seconds.

K>XXXXXX

A pointer (>) appears to indicate hard-key modification is activated.

K>XXXXXX

Press MENU (

) to modify the first hard-key character.

K:>XXXXX

Press EXECUTE to advance to the second hard-key character.

K:>XXXXX

Press MENU (

) to modify the second hard-key character.

K:X>XXXX

Press EXECUTE to advance to the third hard-key character.

K:X>XXXX

Press MENU (

) to modify the third hard-key character.

K:XX>XXX

Press EXECUTE to advance to the fourth hard-key character.

K:XX>XXX

Press MENU (

) to modify the fourth hard-key character.

K:XXX>XX

Press EXECUTE to advance to the fifth hard-key character.

K:XXX>XX

Press MENU (

) to modify the fifth hard-key character.

K:XXXX>X

Press EXECUTE to advance to the sixth hard-key character.

K:XXXX>X

Press MENU (

) to modify the sixth hard-key character.

Press ESCAPE to exit the menu and save the desired hard-key code.

Press RESET to exit the menu without saving.

The menu will automatically timeout after 2 minutes of inactivity and save.

NOTE: Be sure to record and file the hard-key code on page 31 for future reference.

40. SERIAL#

View the microcontroller’s unique six-character silicone serial number.

XXXXXX

Shows the unique six-character serial number.

41. VERSION

View the microcontroller’s software version.

VER X.X

Shows the microcontroller’s software version.

42. EEPROM

View the type of EEPROM memory module plugged in.

All JS-ICON

Series dimmer racks come with a removable EEPROM memory module

located on the MADD-24 board. The EEPROM memory module inserts into the

PORT1 connector located on the upper center of the board, and may be removed for

safe storage.

The EEPROM type is programmed for parameter (P) or firmware (F) operation. A

parameter EEPROM is used to backup all of the current configuration settings. A

firmware EEPROM is used to update the current firmware version running on the

MADD-24 microcontroller to the firmware version saved on the EEPROM.

The EEPROM memory module supplied with all JS-ICON

Series dimmer racks is

a parameter type with all of the factory default configuration settings saved onto it

before shipping.

MADD24-P

Indicates the EEPROM memory module is for a MADD-24 microcontroller.

MADD24-P

Indicates the EEPROM type is programmed for parameter (P) operation.

XXXXXX

Press EXECUTE to display the silicone serial number parameter.

DISABLED

Press EXECUTE and menu feature is disabled for factory use only.

MADD24-F

Indicates the EEPROM type is programmed for firmware (F) operation.

VER X.X

Press EXECUTE to display the version (VER) of the firmware.

DISABLED

Press EXECUTE and menu feature is disabled for factory use only.

NONE!

Indicates the EEPROM memory module is not installed.