Koolance EXT-440CU-R User Manual

Page 13

Advertising
background image

18

19

User Manual

Once all the water blocks have
been connected, the system can

be filled with coolant. The fill port is located on top of
the reservoir. Remove the large slot-headed screw
(with a screwdriver or large coin).

Testing & Filling

WARNING

:

Most coolants are electrically conductive. Use caution

when filling the system, and keep all liquids away from electronics and
power cables. In case of emergency during installation, immediately
unplug the primary AC power cable. Dry the system thoroughly before
proceeding.

!

If your pump has a speed control option, set it to the lowest level during
this time. Allow the pump to run until the liquid noise subsides.

During this process, cooling systems often need to be tilted gently
to allow air to escape from the pump and radiator. Until the pump
is “burped” in this manner, it can cavitate and there will be no
circulation.

(This does NOT indicate a problem with the pump.)

The reservoir level will decrease during this procedure. Remove the fill
port cap and add more liquid when needed. If you frequently hear this
rushing noise in the future, it indicates the need for more coolant.

Replace the fill port on the reservoir. Do not overtighten the fill port.

The cooling system should be powered on to assist in the filling process. This also
allows you to check hose connections and make sure there are no tubing folds,
leaks, or blockages. If cooling a computer, this can be done without powering on
other hardware for extra safety (see below).

CAUTION

:

Jumping the incorrect ATX power supply pins can cause

permanent damage to the power supply.

!

Make sure the AC power cord is attached to the power supply. If the power supply
has a rear switch, it must be set to the ON (-) position. Using the included green
Jumper Wire, insert the metal prongs into the fourth and sixth holes on the 20-24
pin ATX motherboard power supply plug (usually green and a black ground wire;
See diagram

).

That’s it! Replace the ATX motherboard connection and boot-up the computer.

Filling & Maintenance

CAUTION

:

When filling, the

cooling system should be higher
than all other liquid components
to avoid spillage.

!

Slowly fill the system. To maintain the
product warranty, use only Koolance
approved coolant.

Many alternative liquids

and additives can cause permanent dam-
age to the cooling unit (through chemical
reaction, corrosion, biological growth, ther-
mal expansion, viscosity, etc.).

The liquid coolant should be filled to about 6mm (1/4”) from the reservoir’s top. Do
not overfill

.

When empty, the cooling unit should be placed
above all other water blocks when adding liquid.
Otherwise, coolant can be forced out the fill port
instead of into the hoses.