GETTING STARTED

2.3 COOLING

The EPAK 2500R has a comprehensive cooling system featuring chassis-sealed PCB board
mounting and shock mounted, speed controlled fans. This means that the cooling system
never drives air across PCB boards, connectors or components ensuring prolonged
electronic component lifespan and minimizing maintenance cycles.

Air is drawn into the front of the a

er by the two fans on the rear panel, this passes

over the cooling

of the heat sinks and exhausts through the rear. If the heat sink gets

too hot, its sensing circuit will open the output relay, disconnecting the load.

It is important to have an adequate air supply at the front of the ampli

and enough

space around the rear of the ampli

to allow the cooling air to escape. If the unit is

rack mounted, do not use doors or covers on the rear of the rack; the exhaust air must

without restriction. If you are using racks with closed backs, use fans on the rear

rack panel to ensure an ample air supply

2

2.4 AC REQUIREMENTS

A PowerCon cable is provided to connect the EPAK 2500R to a suitable AC power supply.

The PowerCon is a connector without breaking capacity, i.e. the PowerCon
should not be connected or disconnected under load or while it is live.
Always isolate your AC supply before disconnecting the PowerCon connector.

Your EPAK 2500R will be supplied pre set to the voltage used in your area. The table
below provides typical current draw

for the EPAK 2500R.

AC Input

250V

230V

115V

Current draw with

running at Average

Power (Each Channel)

8.25A

9A

18A

Current draw with

running at

Peak Power (Each Channel)

12.5A

14A

28A