Maintenance – Lenze HMI for visualisation / with control technology User Manual
Page 92

Maintenance
Battery replacement
l
92
LDCDS−EL100 EN 9.0
How to proceed:
1. Remove all connected cables and the SD card.
2. Remove the device and put it face−down on a table.
Make sure that the display is not damaged by parts on the table.
3. Remove PC housing:
0
1
1
1
1
0
0
2
3
0
EL100−035
– Loosen 4 screws
0. Do not loosen screw 2!
– Loosen 4 screws
1.
– Carefully remove the housing
3. Please observe that the housing is connected to
the baseboard by a cable (PE connection
2).
4. Exchange battery:
4
EL100−036
– Remove the dead battery
4 from the unit.
– Insert new battery
4with the positive pole up.
5. Mount PC housing:
– Carefully put the housing
3onto the baseboard. The PE cable must not be bent in
the process.
– Insert and tighten 4 screws
0and 4 screws 1.
According to European legislation you are obliged to dispose of batteries separately, using
the take−back systems specified.