Operation 3 – Lenze EZAEDE1000 User Manual
Page 27

EZAEDE1000 DE/EN/FR/IT/ES 1.1
13
Operation
3
3.5
Details of the Copied Data
3.5.1 8400 Series Memory Module
8400 Inverter Type
EPM Attributes
SL
HL
TL
TL Vx
protec
Master memory module
MM100 / E84AYM10S
E84AYM30S
Target memory module
MM100 / E84AYM10S
E84AYM30S
Master drive data from:
can be copied and used in...
SL
HL
TL
TL Vx
protec
target drive = SL
Yes
target drive = HL
Yes
Yes
target drive = TL
Yes
Yes
Yes
target drive = TL Vx
Yes (?)
Yes
target drive = protec
Yes
Data validity check
No
Drive parameters copied
Yes
Vector calibration information copied
Yes
Timer information copied
No
1
Fault history copied
No
1
Inverter based adjustments
No
2
Application and system component adjustments
Yes
3
OEM area created
No (area not available)
Target module is exact copy of Master module
Yes (except headers)
1
Data is not part of memory module contents but is retained in the inverter’s memory.
2
An example of an inverter based adjustment is resolver inverter electronics.
3
An example of an application and system component adjustment is resolver imprecision.