5 memory requirements for sdo, Memory requirements for sdo, Api functions 3 – Lenze 3241C User Manual
Page 19

API
functions
3
17
Response
Structural element
Type
Bits
Description
FIFO
Header
1 DWORD
Value
BYTE
24-31
2. value
Value BYTE
16-23
1.
value
Number of values
BYTE
8-15
Number of bytes
(max. 64)
Status
BYTE
0-7
Status information (0 = OK)
1 DWORD
Values
ARRAY
Other values to be transmitted
n DWORDs
Notes:
All SDOs are to be stored in a DWORD-aligned manner.
Job is completed automatically by the driver.
3.4.5
Memory requirements for SDO
For SDO there are also two directions:
L-force Controller transmits control data/commands to the backplane bus
controller
Backplane bus controller transmits control data/status information to the
L-force Controller
For both directions FIFOs are used as mailbox. The size of the FIFOs is 128 bytes in
each case.