17.1.53
L_ConvW_3
This FB serves to convert analog signal forms. The following conversions per parameter can be
selected:
• [%] [incr/ms]
• [incr/ms] [%]
• Conversion via parameterisable factors
• Input signal is passed through without conversion
Inputs
Outputs
Parameter
Identifier
Data type
Information/possible settings
wIn
WORD
Input signal
Identifier
Data type
Value/meaning
wOut
WORD
Output signal
Parameter
Possible settings
Info
-32767
32767 Numerator
• Lenze setting: 1
-32767
32767 Denominator
• Lenze setting: 1
Selection of the conversion
0 wOut = wIn (no conversion)
1 [%] [incr/ms]
2 [incr/ms] [%]
3 wOut = wIn *
For conversion formulae see
/B&RQY:B
Z2XW
Z,Q
'HQRPLQDWRU
&RQYHUVLRQ
&
&
&
1XPHUDWRU