Trouble shooting, Forcecut 40d and 50d plasma cutters – Longevity FORCECUT 50D User Manual

Page 29

Advertising
background image

ForceCut 40D and 50D plasma cutters

Page 28 of 30

www.longevity-inc.com

Trouble shooting

If your unit is not properly functioning, please call us immediately toll free at 1-877-566-4462

for support. We have included a small table here to diagnose most common problems.

Problems, Causes, and Solutions

Problems

Causes/

Solutions

Machine will not

turn on.

Check cords and breaker. If nothing is found, contact

LONGEVITY

The machine runs,

but nothing is

happening

Check to see if you have the air regulator to the correct pressure.

Make sure the regulator adjustment knob is turned clockwise and

allow pressure. Check the consumables and make sure they are

properly assembled. Check the ground clamp and proper grounding

to the unit. Check pilot arc wire to insure it is properly connected to

the unit.

Consumables

(tips) are being

consumed

Improper air flow. Increase the PSI on the regulator, check for

leaks in the hose, maintain a distance of 1/8” from the torch tip or

work piece.

Heavy Underside

Slag (Cutting)

Slow travel speed. Increase travel speed or amperage on unit.

Poor Cut Quality

Check Air Pressure. Insure your unit is capable of cutting the

desired thickness of material. Check the consumables to insure they

are producing a stable arc. Replace Consumables and insure you

have the proper PSI at the regulator.

Inconsistent

Arc

Improper grounding or possible lack of air pressure. Check and

replace consumables and adjust the regulator to proper PSI

Plasma Cutter

Pilot Does not

Ignite

Check consumables to insure they are super tight. Possibly, replace

the tips. Insure that you have compressed air flowing to the unit.

Drop the PSI pressure.

O.C. Over

Current LED

Lights

The unit has reached its DUTY Cycle. Leave power of the machine

on and allow fans to cool the machine. You can also turn the

machine off to properly cool it. Do not continue to weld until light

is off.

Issue Not Listed

Contact LONGEVITY Toll Free 1-877-566-4462 or via email at

[email protected]