APPENDIX E

Changing the LNT Battery
The LNT Module uses a lithium coin CR2023 battery that will last about 5 years and
is installed with the original LNT Module assembly. After you replace the battery, you
will need to recalibrate the telescope’s sensors and reset the time and date. You will
need a new battery. Also, you may use Meade’s optional Atomic Time Update
Module, although this is not necessary.

To replace the battery:

1. Remove the top alignment screw cap/long bolt from the LNT Module. See

Fig.

33.

2. Remove the side alignment screw cap/long bolt from the LNT Module. Take note

that there are two springs inside the LNT. One spring sits between the top and
bottom of the unit. The second spring is on the side of the unit that rests
between the bottom and the top sections. One long bolt passes through the top
spring and the other long bolt passes through the side spring. Set the springs
aside as you will need to replace it later in this assembly . See

Fig. 33 and 34.

Important Note: Note there is some wiring inside the LNT Module. Be careful
not to pull on the wiring. If it is necessary to move the wiring aside, do so
carefully.

3. Carefully lift the top section of the unit from the bottom section. Do not remove

the bottom section or disassemble the rest of the unit.

4. Remove the old battery. Note the spring.
5. Insert the new (user-supplied) battery. Take care to orient the battery so that the

side with the battery markings is facing the top.

6. Replace the top spring in place and the LNT Module cover.
7. Replace the top bolt and tighten the cap to a firm feel.
8. Hold the side spring in place with your fingers and slide the spring between

between the top and bottom sections. The spring should line up with the
mounting holes for the side long bolt. Slide the long bolt through the side hole,
then through the spring and finally through the bottom of the LNT Module and
tighten to a firm feel.

9. Next, follow the instructions included with the Atomic Time Update Module

optional accessory to reset the clock.

OR

Enter the date and time manually using the Date and Time options in the Setup
menu.

Note: You may find it useful to recalibrate the LNT Module sensors after chang-
ing the battery.. You will find the Calibrate Sensors in the Setup: Telescope
menu.

Top

Alignment

screw hole

Spring

Spring

Battery

Side
Alignment
screw hole

Side
Alignment
screw

Side
Alignment
screw hole

Cover

Top

Alignment

screw

Top

Alignment

screw

Atomic Time
Update Port

Fig. 33: The LNT Module, with
alignment screws and Atomic Time
Update port visible.

Fig. 34: Interior side view of LNT
Module.

Fig. 35 Interior top view of
SmartFinder unit.