PUP-8

U-PANEL

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

PbU-P

anel

s

eCTion

P

roPerTies

and

g

eneral

i

nformaTion

2

1

/

2

"

C

3

1

/

2

"

6"

3

/

4

"

1"

36" Coverage

ALLOWABLE UNIFORM LOADS PSF

(3 or More Equal Spans)

2' 3' 4' 5' 6' 7' 2' 3' 4' 5' 6' 7'

SECTION PROPERTIES

Bottom in Compression

Width

(in.)

Yield

KSI

36"

80

36"

50

36"

50

26

Ga.

24
22

Sxx

In

3

/ft

Ixx

In

4

/ft

Weight

PSF

0.89
1.15
1.48

Top in Compression

Sxx

In

3

/ft

Ixx

In

4

/ft

Inward

Load

Outward

Load

0.0187 0.0349 0.0130 0.0308

209 94 48 25 14 9 313 142 80 52 36 26

0.0273 0.0524 0.0190 0.0482

272 123 70 36 21 13 392 178 101 65 45 33

0.0367 0.0741 0.0267 0.0676

379 172 95 49 28 18 551 251 142 91 64 47

1. Theoretical section properties have been calculated per AISI 2001 “Specification for the Design of Cold-formed Steel Structural Members.” Ixx and Sxx are

effective section properties for deflection and bending.

2. Allowable load is calculated in accordance with AISI 2001 specifications considering bending, shear, combined bending and shear, deflection, and applicable

testing when available. Allowable load considers the worst case of 3 and 4 equal span conditions. Allowable load does not address web crippling or

fasteners/support connection and panel weight is not considered.

3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span.

4. Allowable loads do not include a 1/3 stress increase in uplift.

Slope

Substructure

Coverage

Length

Fasteners

Availability

GENERAL INFORMATION

ATTACHMENT DETAIL

FASTENING PATTERN

The minimum recommended slope for PBU-Panel is 1:12.

Metal Sales recommends that in all roof applications

sealants be used on all sidelaps with stitch screw 1'-0" on

center.

PBU-Panel is designed to be utilized over open structural

framing, but can easily be used with a solid substrate. To

avoid panel distortion, use a properly aligned and uniform

substructure.

PBU-Panel are available in 3/4" rib height with a coverage

width of 36".

Minimum factory cut length is 5'-0". Maximum

recommended panel length is 45'-0". Longer panels

require additional consideration in packaging, shipping, and

erection. Please consult Metal Sales for recommendations.

The fastener selection guide should be consulted for

choosing the proper fastener for specific applications.

Quantity and type of fastener must meet necessary loading

and code requirements.

NOTE: All panels are subject to surface distortion due to

improperly applied fasteners. Overdriven fasteners will

cause stress and induce oil canning across the face of the

panel at or near the point of attachment.

Finishes: Acrylic Coated Galvalume

®

, MS Colorfast45

®

,

or various Kynar 500 (PVDF) colors.

Gauges: 26 ga and 24 ga standard, 22 ga optional

1

/

4

"-14 x

7

/

8

" Stitch Screw

(for roof only)

Tape Sealant

(for roof only)

#12-14 x 1

1

/

4

" Self Driller

1

/

4

"-14 x

7

/

8

" Stitch Screw

(for roof only)

Tape Sealant (for roof only)

#12-14 x 1

1

/

4

" Self Driller

Advertising