MTS FlexTest® Models 40/60/100/200 Controller Hardware

Model 494.26 Dual DUC Card

Mezzanine Cards

158

Model 494.26 Dual DUC Card Settings

Hardware

configuration

Each of the two conditioners on this card has a two-position switch that is
used to set up the following DC conditioner functions:

Switch A connects a bridge completion resistor to -FBR to complete a
quarter-bridge circuit.

Switch B provides a ground reference for an external transducer by
connecting -FBR to ground.

Software configuration

After you set up and install the hardware, you must configure your control
software settings for the conditioner.

Note

For detailed information on software configuration, calibration, and
tuning, see the control software and tuning/calibration
documentation.

1

2

3

4

5

6

7

8

J1A

J1B

J2A

J2B

J3A

J3B

J4A

J4B

OFF

ON

A B

A B

OFF

ON

Switch Settings

A = Bridge Completion Switch
The ON position connects a
user-installed bridge completion
resistor to complete a quarter-
bridge circuit.

B = Grounding Switch
The ON position connects -FBR
line to ground (see the bridge
completion drawings for details).