Model 494.42 Single-Station System Board

About the Model 494.42 Single-Station System Board

The Model 494.42 System Board is a two-
slot board that is only used in the Model
494.04 Chassis. This board provides analog
and digital I/O, E-Stop, HSM, UPS, and
HPU control for one station.

Board features

External Interfaces

•

Three digital inputs (J54)

•

Three digital outputs (J55)

•

Auxiliary power outputs for external
devices (J49)

•

UPS inputs (J56) ACFail and low
battery inputs (switch contacts)

•

Two analog outputs (DA Output
connector on the 494.04 chassis)

Hydraulic Control

•

24-volt HPU control (J25)

•

24-volt HSM control (Off/Low/High or
proportional) for one HSM (J28)

E-Stop/Interlock Control

•

Load-frame E-Stop and crosshead
control for one load frame (J29)

•

Optional E-Stop inputs (J24-located on
the 494.04 chassis)

•

Interlock (J43) provides one interlock
input, one interlock output, and a
software-defined event input

•

E-Stop/Run outputs (J23)

Power

100-240 VAC

50-60 Hz, 1-2 A

DA Output

J24

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

LAN 2

LAN 1

DEBUG

MOT

O

ROLA

10/100 BASE T 10/100 BASE T

SCSI

BUSY

PIB

BUSY

PCI MEZZANINE CARD

PCI MEZZANINE CARD

J54

Dig In

J55 Dig Out

J43 INTLK

J56 UPS

J49

Aux Pwr

J23 Estop/Run

J29 Load Frame

J25 HPU

J28 HSM

J54 Dig In

J55 Dig Out

J43 INTLK

J56 UPS

J49 Aux Pwr J23 Estop/Run

J29 Load Frame J25 HPU

J28 HSM

J49 AUX PWR
Auxiliary DC supply
voltages for external
devices:
+ 5 V DC, +15 V DC,
-15 V DC, +24 V DC

J28 HSM
24-volt control for
HSM off/low/high or
proportional solenoid
plus an HSM Estop
input

J43 Intlk
Interlock input
Interlock output
Event input

J29 Load Frame
Load Frame E-Stop

J25 HPU
24 V DC HPU control
for one HPU channel

J54 Dig In
Digital inputs (3)

J55 Dig Out
Digital outputs (3)

Model
494.04

Chassis

J23 Estop/Run
2 Estop NO outputs
1 set of Run NO/NC
outputs

DA Output (2))

J24 E-Stop
(Optional)

J56 UPS
UPS digital inputs
ACFail, Low battery