Model 494.16 VD/DUC Mezzanine Card

MTS FlexTest® Models 40/60/100/200 Controller Hardware

Mezzanine Cards

161

Specifications–Model 494.16 Valve Driver Card

P

ARAMETER

S

PECIFICATION

Output Current

100 mA maximum per output (software configurable)

Valve Outputs per
Card

2

Dither

Frequency

Amplitude

1 Hz–4915.2 Hz (software adjustable)

0–5 V DC (software adjustable)

Valve Clamping

Software configurable valve clamping setting
performs the following actions when a hydraulic
interlock occurs.

Disabled—Valve does not clamp. This is the
default action if the clamp entry is omitted.

Zero—Clamps the servovalve to zero. If valve
balance is used, it will clamp to this value.

Positive—Clamps the servovalve to positive
50% spool opening on a 2-stage valve driver,
50% outer-loop command on the 3-stage valve
driver.

Negative—Clamps the servovalve to negative
50% spool opening on a 2-stage valve driver,
50% outer-loop command on a 3-stage valve
driver.

Valve Balance
Offset

+/- 10 V DC (software adjustable)

Advertising