Model 494.47 Dual UART/Encoder Interface Card

MTS FlexTest® Models 40/60/100/200 Controller Hardware

Mezzanine Cards

193

Pulse-Width-Modulated (PWM) Connections for the Model 494.47 Card

I/O Carrier Board

Front-Panel

RJ-50 Connectors

JXA and JXB

- Power

- Data

+ Data

+Power

4

5
6

7

Temposonics G

Transducer

(9 to 28-volt power)

JXA

- Power

- Data

+ Data

+Power

4

5
6

7

Temposonics G

Transducer

(9 to 28-volt power)

JXB

Mezzanine

Card

494.47

Dual

UART/

Encoder

Conditioner

Cable Grounding

1 The cable shield connects

to the metal shielding on

the RJ-50 cable plug.

2 The cable plug shielding

connects to the I/O carrier

board body.

3 The I/O carrier board

connects to earth ground

through the chassis.

Temposonics G (PWM) Connections (9- to 28-volt power option)

JXA

+ Data
- Data

5
6

DC Power +

-

Temposonics G

Transducer

(24-volt Power)

I/O Carrier Board

Front-Panel

RJ-50 Connectors

JXA and JXB

JXB

Mezzanine

Card

494.47

Dual UART/

Encoder

Conditioner

+ Data
- Data

5
6

DC Power +

-

Temposonics G

Transducer

(24-volt Power)

Cable Grounding

1 The cable shield connects

to the metal shielding on

the RJ-50 cable plug.

2 The cable plug shielding

connects to the I/O carrier

board body.

3 The I/O carrier board

connects to earth ground

through the chassis.

4 The negative (-) side of

the DC Power must be

connected to signal

ground on the controller

chassis.

Temposonics G (PWM) Connections (standard 24-volt power option)