Specifications–model 494.32 di/o breakout box – MTS FlexTest Models 200 User Manual

Page 222

Advertising
background image

MTS FlexTest® Models 40/60/100/200 Controller Hardware

Model 494.32 8-Channel DI/O Breakout Box

Digital I/O and Transition Boards

222

Specifications–Model 494.32 DI/O Breakout Box

Device connections

Individual input and output connections require a four-position terminal plug
(included with the breakout box). Input and output terminal plugs have
different keying.

Output circuits

Input circuits

For more information

For more information on DI/O power supplies, see

“Model 494.33 Digital I/

O Power Supply”

on page 227.

P

ARAMETER

S

PECIFICATION

Maximum Output Voltage

30 V DC

Maximum Output Current

2 A (per channel)

Output Fuse

3 A, fast-blow fuse (one per channel)

Output Fuse Voltage Drop

0.15 V typical

Output-On Resistance

0.03 ohm maximum

P

ARAMETER

S

PECIFICATION

Input Voltage

3.3 to 24 V DC

Input Current

3.35 mA maximum (Vin = 5 V DC)

18 mA maximum (Vin = 24 V DC)

Input Power Fuses

200 mA, self-resetting
(two per channel)

Logic Input Differential Voltage

3.3 V DC minimum

Advertising