MTS FlexTest Models 200 User Manual

Page 231

Advertising
background image

Model 494.33 Digital I/O Power Supply

MTS FlexTest® Models 40/60/100/200 Controller Hardware

Digital I/O and Transition Boards

231

Circuit Breaker Reset—Model 494.33 DI/O Power Supply

The Model 494.33 DI/O Power Supply includes a circuit breaker that is built
into the power switch.

Important

You should develop a circuit breaker reset procedure based
on a risk assessment for your system.

Reset procedure

1. If required, shut down system hydraulics.

2. Switch the Power switch on the front of the power supply to the off

position.

3. If required, check the controller input/output status to make sure that

they are set to a safe state.

4. Switch the Power switch on the front of the power supply to the on

position.

Switching the power switch off and then on resets the circuit breaker. If
the overcurrent condition still exists, the circuit breaker continues to
trip (remove power) each time it is reset.

Resetting the circuit breaker restores power to digital input and output
(DI/O) devices. Resetting the circuit breaker can result in unexpected
actuator movement and unexpected operation of DI/O devices.

Unexpected actuator movement and operation of DI/O devices can
result in injury to personnel or damage to the equipment.

Follow a circuit breaker reset procedure that is based on a risk assessment
that you performed for your site.

ON OFF

WARNING

Advertising