background image

Model 494.33 Digital I/O Power Supply

MTS FlexTest® Models 40/60/100/200 Controller Hardware

Digital I/O and Transition Boards

235

Power Connections for the Model 494.32 DI/O Breakout Box

To maintain EMC compliance, power cables must comply with the
following specifications.

Note

The maximum cable length for all power cables is 6 m (20 ft).

For cable pin assignments, see

“Power Connections Model 494.32 DI/O

Breakout Box”

on page 236.

Output Pwr cable

Input Pwr cable

Model 494.32 DI/O

Breakout Box

P

ARAMETER

T

O

J1, 494.33 P

OWER

S

UPPLY

T

O

P29, 494.32 B

REAKOUT

B

OX

Connector

4-contact, PT male connector 5-power contact, type D,

female EMI connector

Backshell

Non-conductive with strain
relief

EMI metallized plastic or
metal

Cable

16 AWG, 4-conductor with braided shield connected to the
backshell at the DI/O breakout box only.

P

ARAMETER

T

O

J1, 494.33 P

OWER

S

UPPLY

T

O

J3, 494.32 B

REAKOUT

B

OX

Connector

9-contact, type D, male EMI
connector

15-contact, type D, female
EMI connector

Backshell

EMI metallized plastic or metal

Cable

18 AWG, 4-conductor with braided shield connected to the
backshell at the DI/O breakout box only.