Cable specifications, Jumper plug required – MTS FlexTest Models 200 User Manual

Page 241

Advertising
background image

Model 493.73 HPU Interface Board

MTS FlexTest® Models 40/60/100/200 Controller Hardware

Digital I/O and Transition Boards

241

J24 E-Stop Input Connections for the Model 493.73 HPU Interface Board

Connector J24 E-STOP In provides an input for an external emergency stop
switch.

Note

Emergency stop inputs are part of a controller-wide E-Stop system.

Cable specifications

To maintain EMC compliance, 24 E-STOP In cables must comply with the
following specifications:

Connector —15-contact, type D, male EMI connector.

Backshell–EMI metallized plastic or metal.

Cable–24 AWG 4-connector with overall braided shield connected to
metallized plastic backshell at the chassis and to ground at the emergency
stop station.

Jumper plug required

If connector J24 is not used, you must install a jumper plug to maintain the
integrity of the interlocks. Use jumper plug part number 039-713-201 or
jumper pins: 5 and 7; 8 and 13.

SERVICE

493.73

HPU

J29

E-STOP OUT

J24

E-STOP IN

J25 HPU

J54

SYS D I/O

+24 V

E-Stop

Out Relay

E-Stop

493.73 HPU Board

J24

E-STOP IN

13

8

7

5

E-Stop

Controller

Signal

J24

E-STOP IN

Advertising